Brother Furnace

Inert Atmosphere Furnace

High Temperature Inert Atmosphere Furnace up to 1700°C

This controlled inert atmosphere heat treatment furnace is pre-vacuumed to ensure that the oxygen content in the furnace is minimized, and then nitrogen, argon is introduced to obtain the desired heating treatment under the protection of the atmosphere. Due to its excellent atmosphere and compactness, it has been widely used in material laboratories or small batch production of semiconductors, silicon nitride, and other products.

Features:

Standard spares:

Additional spares:

 

Atmosphere furnace with auto mixing system

Inert Atmosphere Furnace Operation

Ⅰ. Technical Specifications

Max. temperature 1700℃ (<2hour)
Working temperature 1600℃
Standard Temperature controlling ●  PID automatic control via SCR (Silicon Controlled Rectifier) power control with phase angle fired, current limiting resistor.
●  51 programmable segments for precise control of heating rate, cooling rate and dwell time.
●  Built in PID Auto-Tune function with overheating & broken Thermocouple broken protection.
●  Over temperature protection and alarm allows for operation without attendant
Optional of Temperature controlling ●  Software (Furnace can be operated by PC by installing a control software)
●  Touch screen temperature controller
Temperature accuracy ±1℃
Temperature Uniformity ±5℃ over 120mm @ 1600℃
±3℃ over 80mm @ 1600℃
Heating rate 0-15℃ /min
Thermocouple B type (Pt-Rh) with 99.7% purity Alumina tube
Heating element U type MoSi2 heating element
Furnace Chamber Three layers of ceramic fiber insulation materials
●  First layer: 1800℃ ceramic fiber board.
●  Second layer: 1600℃ ceramic fiber board.
●  Third layer: 1430℃ ceramic fiber board.
Furnace structure Double layer steel casing with dual cooling fan, surface temperature below 60℃
Furnace door ●  Power cutting off when furnace door open
Warranty ●  One year limited warranty with life time support. (Consumable parts such as heating elements and crucibles are not covered by the warranty, please order the replacement at related products)
●  ATTENTION: Any damages caused by the use of corrosive and acidic gases are not under the coverage of One Year Limited Warranty.
Certifications CE

Ⅱ. Application Notes

Using Attentions ●  Cooling rate shall also not exceed 10℃/min.
●  Toxic or explosive gases are not recommended for use with this furnace without necessary safety controls and supervision.
●  Small cracks may appear on the surface of the refractory ceramics over extended use. This is a normal occurrence and the cracks may be repaired with alumina coating.
●  Refractory door block must be inserted before closing door.

 

Inert Atmosphere Furnace up to 1200°C

Model Max. Temp. Chamber size Voltage Power
BR-12AN-1 1200℃ 100*100*100mm 220V 0.8kW
BR-12AN-2 1200℃ 120*120*130mm 220V 1.2kW
BR-12AN-3 1200℃ 150*150*150mm 220V 2.5kW
BR-12AN-5 1200℃ 150*150*200mm 220V 3kW
BR-12AN-8 1200℃ 200*200*200mm 220V 5kW
BR-12AN-12 1200℃ 200*200*300mm 220V 6kW
BR-12AN-27 1200℃ 300*300*300mm 380V 8kW
BR-12AN-36 1200℃ 300*300*400mm 380V 10kW
BR-12AN-64 1200℃ 400*400*400mm 380V 16kW

 

Inert Atmosphere Furnace up to 1400°C

Model Max. Temp. Chamber size Voltage Power
BR-14AS-1 1400℃ 100*100*100mm 220V 1kW
BR-14AS-2 1400℃ 120*120*130mm 220V 2kW
BR-14AS-3 1400℃ 150*150*150mm 220V 3kW
BR-14AS-5 1400℃ 150*150*200mm 220V 4kW
BR-14AS-8 1400℃ 200*200*200mm 220V 5kW
BR-14AS-12 1400℃ 200*200*300mm 220V 7kW
BR-14AS-27 1400℃ 300*300*300mm 380V 9kW
BR-14AS-36 1400℃ 300*300*400mm 380V 11kW
BR-14AS-64 1400℃ 400*400*400mm 380V 18kW

 

Inert Atmosphere Furnace up to 1700°C

Model Max. Temp. Chamber size Voltage Power
BR-17AM-1 1700℃ 100*100*100mm 220V 1kW
BR-17AM-2 1700℃ 120*120*130mm 220V 3kW
BR-17AM-3 1700℃ 150*150*150mm 220V 4kW
BR-17AM-5 1700℃ 150*150*200mm 220V 5kW
BR-17AM-8 1700℃ 200*200*200mm 220V 7kW
BR-17AM-12 1700℃ 200*200*300mm 220V 8kW
BR-17AM-27 1700℃ 300*300*300mm 380V 10kW
BR-17AM-36 1700℃ 300*300*400mm 380V 12kW
BR-17AM-64 1700℃ 400*400*400mm 380V 20kW

 

Note: This inert atmosphere heat treatment furnace can not be used in hydrogen.

If you need hydrogen, check out our Hydrogen Atmosphere Furnace.

If you need a high vacuum, check out our vacuum Furnace

 

Follow us on Facebook

Exit mobile version